dormakaba LA GARD Basic 700 - Changing Batteries

dormakaba LA GARD Basic 700 - Changing Batteries

Posted by Jim Noort on 22nd Nov 2026

Blog banner - changing the batteries on a dormakaba LA GARD Basic 700 safe keypad, Terry's Gold Coast Safes

Changing the Batteries on a dormakaba LA GARD Basic 700

Flat batteries are the most common reason a safe will not open — and the most avoidable. Here is what the warning signals mean, which batteries the Basic 700 takes, and when to act on them.

The dormakaba LA GARD Basic 700 tells you well before it dies. It gives one warning when the batteries are getting low and a second, much more insistent one when the lock is no longer safe to operate. Miss both and the safe stops opening.

This guide covers:

  • The two warning signals — five beeps and ten beeps — and what each one is telling you
  • Which batteries the keypad takes, and how often dormakaba says to change them
  • How to change them without losing your code
  • What to do when the keypad is already dead
  • The mains power option, if you would rather not think about batteries at all

Everything below comes from dormakaba’s own LA GARD 700 Series guide (PDF), which you can download at the bottom of this page.

Reviewed and published November 2026.

First: Check You Have a Basic 700

Two different dormakaba locks wear the LA GARD 700 name, and the battery behaviour is not the same. The Basic 700 is the one fitted as standard to Sentinel safes.

The round dormakaba LA GARD Basic 700 digital keypad fitted as standard to Sentinel safes

The quick test: press #. On a Basic 700 the backlight comes on and nothing else happens. On a 701 to 705 keypad, # is answered with a green LED.

The dormakaba LA GARD Basic 700 keypad, stocked as standard on Sentinel safes.

Other keypads, other batteries.
A Format DL safe uses a Sargent & Greenleaf keypad, and most Dominator safes use a Tecnosicurezza Pulse 2. Their battery arrangements differ, so do not apply the figures on this page to them.
dormakaba logo

LA GARD is dormakaba’s safe lock brand. On the Basic 700 the keypad carries the batteries and the lock body carries the codes — which is why a battery change is a battery change, and nothing more.

The Two Warning Signals

The Basic 700 has no screen, so both warnings arrive as a repeated beep-and-flash. The difference between them is how many times the signal repeats, and when you hear it.

Low Battery Warning — Five Repeats

The keypad repeats the signal five times while you are opening the lock. The safe still works normally. This is the polite warning: the batteries are low and should be replaced.

Act on this one. It is the cheap, convenient moment to deal with it.

Critical Low Battery Warning — Ten Repeats

The keypad responds to any key press by repeating the signal ten times. dormakaba is blunt about what this means: the lock cannot be safely operated, and the batteries must be replaced before the lock will operate at all.

Ten repeats means stop.
Do not keep entering the code hoping it opens. Replace the batteries first. If the safe is open when you hear this, leave it open until the new batteries are in and the code has been tested.
The Low Battery and Battery Replacement section from the dormakaba LA GARD 700 Basic operating instructions, showing the five-repeat and ten-repeat warning signals
The two battery warnings as dormakaba prints them (page 10). The small red symbols are the keypad’s beep-and-flash signal, repeated five or ten times.
Beeping, or a penalty period?
A keypad that flashes every ten seconds and ignores the number keys is not flat — it is serving a five-minute wrong try penalty after four incorrect codes. See changing the code for that one.

Which Batteries, and How Often

  • Type: 9-volt alkaline. dormakaba specifies high quality alkaline cells and nothing else — no rechargeables, no carbon-zinc, no supermarket bargain multipacks.
  • How many: the battery box and tray take two 9-volt batteries. The system will run on one, but dormakaba does not recommend it.
  • How often: once a year, warning or no warning.
Put it on a date you already remember.
Tie the annual change to something fixed — the end of the financial year, a birthday, the day the smoke alarm batteries get done. A safe that is only opened a few times a year is exactly the one that strands you, because you are never there to hear the first warning.
Change both, change them together.
Replace the pair at the same time with two new cells of the same brand. Mixing a new battery with a part-used one shortens the life of both and muddies the warning signals.

Changing the Batteries

Do It With the Door Open

If the batteries are reachable from outside the safe, this is a two-minute job and the door can stay shut. If your battery box sits inside the safe, open the door first and keep it open until the new batteries are in and the code has been tested. A safe that loses power mid-change with the door closed is a locksmith call.

The Steps

  1. Open the safe door and leave it open.
  2. Open the battery box and lift out the tray.
  3. Take out both 9-volt batteries.
  4. Fit two fresh 9-volt alkaline batteries, matching the polarity on the tray.
  5. Return the tray and close the box.
  6. Enter your code and confirm the bolt retracts. Do it a second time.
  7. Only then close the door.
Not sure where your battery box is?
Sentinel does not publish the battery location for its safes, and it is not the same on every model. The video below walks through the change. If yours looks different, send us a photo and we will point you at it.

Your Code Is Not Affected

Nothing in dormakaba’s battery instructions asks you to re-enter, re-program or reset a code. The only documented way a Basic 700 returns to the factory combination of 123456 is a deliberate reset with a 700 Series Reset Box — which is a separate procedure, done on an open safe, with a tool you would have to be holding.

Change the batteries and your code is the code you had.

Watch the Battery Change

The job from start to finish, on a real safe.

Changing the batteries on a dormakaba LA GARD Basic 700 keypad.

New Batteries In and Still Nothing

Work through these before assuming the lock has failed.

Read What the Keypad Is Telling You

With no screen, the Basic 700 answers in two signals: a double signal means the entry was valid and accepted, a triple signal means it was invalid. If you fumble an entry, wait thirty seconds and start again rather than pressing on.

And remember the four-second rule: once a valid code is accepted, the bolt can only be retracted within four seconds. A code that works but a door that will not open is often just a slow hand on the handle.

Extract from the dormakaba LA GARD 700 Basic operating instructions listing the lock operating and navigation rules, including the double and triple signals
Lock operating and navigation, from dormakaba’s LA GARD 700 Basic operating instructions (page 7).

Five Beeps and No Response

If the keypad has power but the lock is not detected within ten seconds, the keypad gives an error signal five times. That is a connection fault between keypad and lock body, not a battery fault. Press any number key to make it check the connection again.

On a safe that has just been moved, knocked or re-installed, this is the signal to expect — the cable into the lock body’s ENT port has usually been disturbed. That is a job for us, not a screwdriver and a torch.

Do not keep trying codes.
Four consecutive invalid codes start a five-minute penalty, and two more after that start another. If the safe is not opening, stop and call us — see also opening a safe.

The Mains Power Option

The Basic 700 supports AC power. dormakaba lists the 700 Series AC Power Supply (part number 701131) among the accessories the Basic is compatible with, alongside the 700 Series Battery Box (part number 704055).

It suits a safe that is opened many times a day, or one installed where a battery change means moving furniture. It is not a substitute for knowing where your batteries are — but it does take the annual change off your list.

Worth considering?
Talk to us about fitting mains power to your safe, or about the right accessory for the model you have.

Which Safes Use This Keypad

The dormakaba LA GARD Basic 700 is the digital keypad we stock across the Sentinel Safes range:

A Ross 700 key lock or a LA GARD 3390 three-wheel combination dial is a special order through Sentinel. Neither uses batteries — worth knowing if the safe lives somewhere a battery change is awkward. Contact us for a price and a lead time.

Downloads

Keep a copy off the safe.
Save the PDF to your phone, not to a folder inside the safe. The day you need it is the day you cannot open the door.

Frequently Asked Questions

What batteries does a LA GARD Basic 700 take?

Two 9-volt alkaline batteries, held in the keypad's battery box and tray. dormakaba specifies high quality alkaline cells. The system will operate on a single 9-volt battery, but that is not recommended.

How often should I change them?

Once a year, whether or not you have heard a warning. A safe that is rarely opened is the one most likely to strand you, because nobody is there to hear the first warning.

My keypad beeps five times when I open the safe. What does that mean?

That is the low battery warning. The safe still works, but the batteries are low and should be replaced soon.

My keypad beeps ten times on every key press and will not open. What now?

That is the critical low battery warning. dormakaba states the lock cannot be safely operated and the batteries must be replaced before it will work. Replace them before trying the code again.

Will I lose my code when I change the batteries?

No. Nothing in dormakaba's battery instructions asks you to re-enter or reset a code. The only documented way the lock returns to the factory combination of 123456 is a deliberate reset using a 700 Series Reset Box on an open safe.

The batteries are inside the safe and it will not open. What can I do?

Do not keep entering the code - four wrong attempts start a five-minute penalty. Call Terry's Gold Coast Safes. Depending on the safe there may be an external power option, and if not, opening it is a locksmith job.

Can I run the keypad on mains power instead?

Yes. The Basic 700 has an AC power option, and dormakaba lists the 700 Series AC Power Supply, part number 701131, among the accessories it is compatible with. Contact us about fitting it to your safe.

Can I use rechargeable 9-volt batteries?

dormakaba specifies high quality 9-volt alkaline batteries. Rechargeable cells hold a lower voltage and fall away sharply at the end of their charge, which is exactly the behaviour you do not want in a lock that warns you by voltage.

Related Guides

REFERENCE BLOG
Changing the Code on a LA GARD Basic 700

Both code-change methods, the factory 123456, the Super Master Reset Code and the wrong try penalty.

SERVICE
Opening a Safe

What we can do about a safe that will not open - flat batteries, lost codes and failed locks.

SERVICE
Servicing a Safe

Scheduled servicing for safe locks and boltwork, and what a service covers.

REFERENCE BLOG
Common Signs Your Safe Needs Servicing

The warnings that come before a lock fails - stiff handles, intermittent keypads and dragging bolts.

REFERENCE BLOG
What Are Relockers?

The secondary locking devices inside a safe, why they fire, and what it means when one does.

BROWSE
Sentinel Safes

The Defender, Sniper, Protector and Timeless ranges, stocked with the LA GARD Basic 700 keypad.

Flat Keypad, or a Safe That Will Not Open?

Tell us what the keypad is doing and we will tell you whether it is a battery, a cable or a lock.

Ask an Expert
Prefer to bring it in, or see a safe in person?

Terry’s Gold Coast Safes
2 Prosper Crescent
Burleigh Heads, QLD 4220